DOM Seamless Tubes
DOM Tubing (Drawn over Mandrel) is a cold drawn 1020 to 1026 or ST52.3 grade seamless steel tube to drawing to size. Cold drawing DOM to size allows for higher yield and tensile strengths. In comparison to other tubing, DOM is produced to more exact OD and ID tolerances. This allows for minimal machine time and has the highest strength possible.
DOM tubing
- Stockedand produced various size range
- Cut to length service available
- Suitable to hone sizes
- Custom sizes available upon request
- All the common off road sizes available
Benefits of DOM Tubing (Drawn over Mandrel):
- Uniform wall thickness with close OD and ID tolerances
- Uniform grain structure and controlled hardness
- High Yield and Tensile Strength
- Smooth and Clean OD and ID surfaces
- OD and ID concentric
- Excellent machining characteristics
APPLICATIONS
- Hydraulic Cylinders
- Auto and Truck Axles
- Suspension parts and shock absorbers
- High Speed Shafts and rollers
- Bearings and Spacers
- Roll cages
- Agricultural components and many other machined tubular parts.
- Pre-honed tube
Quality Standards:
- EN10305 Steel Tubes for Precision Applications Seamless Cold Drawn Tubes
- DIN 2391 Seamless Precision Steel Tubes
- ASTM A519 Seamless Carbon and Alloy Steel Mechanical Tubing
Composition & Strength
Grade | Chemistry | % | Yield | Tensile | Elongation | Typical Hardness |
PSI | PSI | % in 2″ section | Min | |||
1020 | Carbon | 0.150 – 0.200 | 60000 | 70000 | 10 | B-75 |
MN | 0.300 – 0.600 | |||||
P | 0.035 Max | |||||
S | 0.035 Max | |||||
1026 | Carbon | 0.220 – 0.280 | 70000 | 80000 | 10 | B-80 |
MN | 0.600 – 0.900 | |||||
P | 0.035 Max | |||||
S | 0.035 Max | |||||
ST52.3 | Carbon | 0.140 – 0.180 | 75000 | 85000 | 15 | B-80 |
Si | 0.150 – 0.300 | |||||
MN | 1.200 – 1.400 | |||||
P | 0.020 max | |||||
S | 0.010 max |
Diameter Tolerances
OD Inches | Wall: | OD Inches | ID Inches | ||
Size Range | Percent of OD | Plus | Minus | Plus | Minus |
Up to 0.499 | All | 0.004 | 0 | ||
0.500-1.699 | All | 0.005 | 0 | 0 | 0.005 |
1.700-2.099 | All | 0.006 | 0 | 0 | 0.006 |
2.100-2.499 | All | 0.007 | 0 | 0 | 0.007 |
2.500-2.899 | All | 0.008 | 0 | 0 | 0.008 |
2.900-3.299 | All | 0.009 | 0 | 0 | 0.009 |
3.300-3.699 | All | 0.01 | 0 | 0 | 0.01 |
3.700-4.099 | All | 0.011 | 0 | 0 | 0.011 |
4.100-4.499 | All | 0.012 | 0 | 0 | 0.012 |
4.500-4.899 | All | 0.013 | 0 | 0 | 0.013 |
4.900-5.299 | All | 0.014 | 0 | 0 | 0.014 |
5.300-5.549 | All | 0.015 | 0 | 0 | 0.015 |
5.550-5.999 | Under 6 | 0.01 | 0.01 | 0.01 | 0.01 |
6 and Over | 0.009 | 0.009 | 0.009 | 0.009 | |
6.000-6.499 | Under 6 | 0.013 | 0.013 | 0.013 | 0.013 |
6 and Over | 0.01 | 0.01 | 0.01 | 0.01 | |
6.500-6.999 | Under 6 | 0.015 | 0.015 | 0.015 | 0.015 |
6 and Over | 0.012 | 0.012 | 0.012 | 0.012 | |
7.000-7.499 | Under 6 | 0.018 | 0.018 | 0.018 | 0.018 |
6 and Over | 0.013 | 0.013 | 0.013 | 0.013 | |
7.500-7.999 | Under 6 | 0.02 | 0.02 | 0.02 | 0.02 |
6 and Over | 0.015 | 0.015 | 0.015 | 0.015 | |
8.000-8.499 | Under 6 | 0.023 | 0.023 | 0.023 | 0.023 |
6 and Over | 0.016 | 0.016 | 0.016 | 0.016 | |
8.500-8.999 | Under 6 | 0.025 | 0.025 | 0.025 | 0.025 |
6 and Over | 0.017 | 0.017 | 0.017 | 0.017 | |
9.000-9.499 | Under 6 | 0.028 | 0.028 | 0.028 | 0.028 |
6 and Over | 0.019 | 0.019 | 0.019 | 0.019 | |
9.500-9.999 | Under 6 | 0.03 | 0.03 | 0.03 | 0.03 |
6 and Over | 0.02 | 0.02 | 0.02 | 0.02 | |
10.000-10.999 | All | 0.034 | 0.034 | 0.034 | 0.034 |
11.000-11.999 | All | 0.035 | 0.035 | 0.035 | 0.035 |
12.000-12.999 | All | 0.036 | 0.036 | 0.036 | 0.036 |
13.000-13.999 | All | 0.037 | 0.037 | 0.037 | 0.037 |
14.000-15.000 | All | 0.038 | 0.038 | 0.038 | 0.038 |
Wall Tolerance
Wall Thickness | Including .375″ to .875″ OD | Over .875″ to 1.875″ OD | Over 1.875″ to 3.750″ OD | Over 3.750 “to 15.000” OD | ||||
(Inches) | Plus | Minus | Plus | Minus | Plus | Minus | Plus | Minus |
0.035 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | 0.002 | ||
0.049 | 0.002 | 0.002 | 0.002 | 0.003 | 0.002 | 0.003 | ||
0.065 | 0.002 | 0.002 | 0.002 | 0.003 | 0.003 | 0.003 | 0.004 | 0.004 |
0.083 | 0.002 | 0.002 | 0.002 | 0.003 | 0.003 | 0.003 | 0.004 | 0.005 |
0.095 | 0.002 | 0.002 | 0.002 | 0.003 | 0.003 | 0.003 | 0.004 | 0.005 |
0.109 | 0.002 | 0.003 | 0.002 | 0.004 | 0.003 | 0.003 | 0.005 | 0.005 |
0.12 | 0.003 | 0.003 | 0.002 | 0.004 | 0.003 | 0.003 | 0.005 | 0.005 |
0.134 | 0.002 | 0.004 | 0.003 | 0.003 | 0.005 | 0.005 | ||
0.148 | 0.002 | 0.004 | 0.003 | 0.003 | 0.005 | 0.005 | ||
0.165 | 0.003 | 0.004 | 0.003 | 0.004 | 0.005 | 0.006 | ||
0.18 | 0.004 | 0.004 | 0.003 | 0.005 | 0.006 | 0.006 | ||
0.203 | 0.004 | 0.005 | 0.004 | 0.005 | 0.006 | 0.007 | ||
0.22 | 0.004 | 0.006 | 0.004 | 0.006 | 0.007 | 0.007 | ||
0.238 | 0.005 | 0.006 | 0.005 | 0.006 | 0.007 | 0.007 | ||
0.259 | 0.005 | 0.006 | 0.005 | 0.006 | 0.007 | 0.007 | ||
0.284 | 0.005 | 0.006 | 0.005 | 0.006 | 0.007 | 0.007 | ||
0.3 | 0.006 | 0.006 | 0.006 | 0.006 | 0.008 | 0.008 | ||
0.32 | 0.007 | 0.007 | 0.007 | 0.007 | 0.008 | 0.008 | ||
0.344 | 0.008 | 0.008 | 0.008 | 0.008 | 0.009 | 0.009 | ||
0.375 | 0.009 | 0.009 | 0.009 | 0.009 | ||||
0.4 | 0.01 | 0.01 | 0.01 | 0.01 | ||||
0.438 | 0.011 | 0.011 | 0.011 | 0.011 | ||||
0.46 | 0.012 | 0.012 | 0.012 | 0.012 | ||||
0.48 | 0.012 | 0.012 | 0.012 | 0.012 | ||||
0.531 | 0.013 | 0.013 | 0.013 | 0.013 | ||||
0.563 | 0.013 | 0.013 | 0.013 | 0.013 | ||||
0.58 | 0.014 | 0.014 | 0.014 | 0.014 | ||||
0.6 | 0.015 | 0.015 | 0.015 | 0.015 | ||||
0.625 | 0.016 | 0.016 | 0.016 | 0.016 | ||||
0.65 | 0.017 | 0.017 | 0.017 | 0.017 |
Ovality shall be within the above tolerances except when the wall thickness is less than 3% of the OD. In those cases the additional ovality shall be as follows, but the mean diameter shall be within the specified tolerance.
Outside Diameter | Additional Ovality Tolerance (Inches) |
(Inches) | |
Up to 2 | 0.01 |
Over 2 – 3 | 0.015 |
Over 3 – 4 | 0.02 |
Over 4 – 5 | 0.025 |
Over 5 – 6 | 0.03 |
Over 6 – 7 | 0.035 |
Over 7 – 8 | 0.04 |
Over 8 – 9 | 0.045 |
Over 9 – 10 | 0.05 |
Over 10 – 11 | 0.055 |
Over 11 – 12 | 0.06 |
Over 12 – 12.500 | 0.065 |
Outside Diameter | Straightness Tolerance for any 3′ of Length |
< 8.000″ | 0.030″ |
≥ 8.000″ | 0.060″ |
Pressure Ratings, Steel Tubing for General Hydraulic System Applications
The following chart lists the nominal pressure ratings of tubing products which conform to SAE J524, SAE J525, SAE J526 and SAE J365.
Nominal Tube O.D. | Nominal Tube Wall Thickness | ||||||||||||
0.028 | 0.035 | 0.049 | 0.065 | 0.083 | 0.093 | 0.109 | 0.120 | 0.134 | 0.148 | 0.156 | 0.188 | ||
inch | mm | 0.71mm | 0.89mm | 1.24mm | 1.65mm | 2.11mm | 2.41mm | 2.77mm | 3.05mm | 3.40mm | 3.76mm | 3.96mm | 4.78mm |
Reference Working Pressures at 4:1 Design Factor(psi/MPa) | |||||||||||||
0.125 | 6650 | 8450 | |||||||||||
3.18 | 46.0 | 58.5 | |||||||||||
0.188 | 4250 | 5450 | |||||||||||
4.77 | 29.5 | 37.5 | |||||||||||
0.250 | 3100 | 3950 | 5750 | 7800 | |||||||||
6.35 | 21.5 | 27.0 | 39.5 | 54.0 | |||||||||
0.312 | 2450 | 3100 | 4500 | 6150 | |||||||||
7.92 | 16.8 | 21.5 | 31.0 | 42.5 | |||||||||
0.375 | 2000 | 2550 | 3650 | 5000 | 6550 | 7600 | |||||||
9.53 | 13.8 | 17.6 | 25.0 | 34.5 | 45.0 | 52.5 | |||||||
0.500 | 1850 | 2700 | 3650 | 4800 | 5550 | 6450 | 7200 | ||||||
12.70 | 12.8 | 18.6 | 25.0 | 33.0 | 38.5 | 44.5 | 49.5 | ||||||
0.625 | 1500 | 2100 | 2850 | 3750 | 4350 | 5050 | 5600 | ||||||
15.88 | 10.4 | 14.5 | 19.6 | 26.0 | 30.0 | 35.0 | 38.5 | ||||||
0.750 | 1200 | 1750 | 2350 | 3050 | 3550 | 4150 | 4600 | ||||||
19.05 | 8.3 | 12.0 | 16.2 | 21.0 | 24.5 | 28.5 | 31.5 | ||||||
0.875 | 1050 | 1500 | 2000 | 2600 | 3000 | 3500 | 3900 | ||||||
22.23 | 7.2 | 10.4 | 13.8 | 18.0 | 20.5 | 24.0 | 27.0 | ||||||
1.000 | 900 | 1300 | 1750 | 2250 | 2600 | 3000 | 3350 | 3800 | 4200 | ||||
25.40 | 6.2 | 9.0 | 12.0 | 15.5 | 18.0 | 20.5 | 23.0 | 26.0 | 29.0 | ||||
1.125 | 1150 | 1550 | 2000 | 2300 | 2650 | 2950 | 3300 | 3700 | |||||
28.58 | 7.9 | 10.6 | 13.8 | 15.8 | 18.2 | 20.5 | 23.0 | 25.5 | |||||
1.250 | 1000 | 1350 | 1750 | 2050 | 2350 | 2650 | 2950 | 3300 | 3500 | 4300 | |||
31.75 | 6.9 | 9.3 | 12.0 | 14.2 | 16.2 | 18.2 | 20.5 | 23.0 | 24.0 | 29.5 | |||
1.500 | 1150 | 1450 | 1700 | 1950 | 2150 | 2450 | 2700 | 2850 | 3500 | ||||
38.10 | 7.9 | 10.0 | 11.8 | 13.5 | 14.8 | 16.8 | 18.6 | 19.6 | 24.0 | ||||
1.750 | 950 | 1250 | 1450 | 1650 | 1850 | 2050 | 2300 | 2400 | 2950 | ||||
44.45 | 6.6 | 8.6 | 10.0 | 11.4 | 12.8 | 14.2 | 15.8 | 16.6 | 20.5 | ||||
2.000 | 850 | 1100 | 1250 | 1450 | 1600 | 1800 | 2000 | 2100 | 2550 | ||||
50.80 | 5.9 | 7.6 | 8.6 | 10.0 | 11.0 | 12.4 | 13.8 | 14.5 | 17.6 |
*Calculation of Design Pressures for Alternate Tubing Materials
*Design pressures for alternate tubing materials may be calculated using the Lame formula as follows: P=S((D2-d2)/(D2+d))where:
D= nominal outside diameter of tubing
d= nominal inside diameter of tubing
P= design pressure
S= allowable fiber stress of material at 4:1 design factor
Experienced 15+ Years
Our ability to purchase materials directly from leading mills at the best possible price will give you the competitive edge. This coupled with a skilled workforce dedicated to embracing the demands of the markets.
We Can Supply Follows Products with High Quality:
- Cold Rolled Steel Tube
- Cold Drawn Steel Tube
- Hollow Bar
- Honed Tube
- Plated Tube
- Plated Bar
- Boiler Tube
All Products According Quality Standard Strictly:
- ASTM: ASTM A519, ASTM A513.
- JIS:JIS G3441, JIS G3445, JIS G3466, JIS G3459.
- DIN: DIN1626, DIN1629, DIN2391, DIN2393, DIN2448, DIN2458.
- EN: EN10305.
- BS: BS6323.
Wide Range of Pipes to Fit Your Industry:
- OD from 5mm to 820mm.
- Wall Thickness from 0.1 to 100mm.
- Length up to 50mtr per pc.
Can’t Find What You Looking for? Check Popular Items Blew.
Direct from the Source and Deliver to You in a Very Fast and Efficient Timeframe.